<strike id="6a0go"></strike>
  • <ul id="6a0go"><sup id="6a0go"></sup></ul>
  • <strike id="6a0go"><menu id="6a0go"></menu></strike><strike id="6a0go"><input id="6a0go"></input></strike>
    
    
  • <strike id="6a0go"></strike>
    <strike id="6a0go"></strike>
    <strike id="6a0go"></strike>
    歡迎訪問(wèn)詠繹電子科技(蘇州)有限公司網(wǎng)站,我們竭誠(chéng)為您提供合格產(chǎn)品和專業(yè)的服務(wù)!服務(wù)熱線:0512-68051240
    產(chǎn)品分類·product

    我們相信合格的產(chǎn)品是信譽(yù)的保證!

    相關(guān)文章·articles

    致力于成為合格的解決方案供應(yīng)商!

    產(chǎn)品中心/ products

    您的位置:首頁(yè)  -  產(chǎn)品中心  -    -    -  FLUKE PM3380B示波器

    FLUKE PM3380B示波器

    0

    • 產(chǎn)品型號(hào):
    • 廠商性質(zhì):代理商
    • 更新時(shí)間:2025-02-22
    • 訪  問(wèn)  量:1010
    立即咨詢

    聯(lián)系電話:0512-68051240

    產(chǎn)品詳情

     
     The Fluke PM 3380B ...94B series are the world's first AutoRanging Digital Storage Oscilloscopes with a complete Analog Oscilloscope built in.

    Fluke CombiScopes® are a powerful combination of a genuine analog oscilloscope and a powerful digital oscilloscope in one instrument. Designed to fit any budget, there are 5 models in the CombiScope B series: three 2 channel models with bandwidths of 60, 100 or 200 MHz and two 4 channel models with 100 or 200 MHz bandwidth.

    Fluke CombiScopes offer the best of both worlds:

    PM3380BAnalog Mode Specifications
    Vertical Deflection (PM 3380B/90B) Input Channels: 2 Channels + Ext Trig View 
    Frequency Response:  100 MHz 
    Deflection Coefficient: Ch1 & Ch2 (all models): 2 mV/div . 5 V/div in a 1-2-5 sequence or 2 mV/div to 12.5 V/div calibrated continuously variable 
    Rise Time (Calculated):  1.75 ns
    Error Limit: 1.3% (Measured over center 6 divisions) 
    Input Impedance: (all models, all channels) 1 MΩ Â±1% // 25 pf ±2 pf 
    Max. Rated input voltage: In 1 MΩ position: 150 Vrms CAT II
    In 50Ω position: 5 Vrms; 50V ac peak ( max of 50 mJ during any 100 ms interval. 
     
    Vertical Deflection (PM 3384B/94B) Input Channels: 4 Channels
    Frequency Response: 200 MHz 
    Deflection Coefficient: Ch1 & Ch2 (all models): 2 mV/div . 5 V/div in a 1-2-5 sequence or 2 mV/div to 12.5 V/div calibrated continuously variable 
    Ch3 & Ch4 (PM 3384B/94B): 2 mV/div . 5 V/div in a 1-2-5 sequence or 2 mV/div to 12.5 V/div calibrated continuously variable 
    Rise Time (Calculated): 1.75 ns 
    Error Limit: 1.3% (Measured over center 6 divisions) 
    Input Impedance: (all models, all channels) 1 MΩ Â±1% // 25 pf ±2 pf 
    (PM 3390B/94B): user selectable 50Ω Â±1% 
    Max. Rated input voltage: In 1 MΩ position: 150 Vrms CAT II 
    In 50Ω position: 5 Vrms; 50V ac peak ( max of 50 mJ during any 100 ms interval. 
     
    Horizontal (Main & Delayed Timebases) Display Modes: Main Timebase (MTB), Delayed Timebase (DTB), Alternate Timebase ( MTB & DTB), X-Y Mode.
    Time Coefficients: (PM 3380B/3384B): 0.5 s/div to 50 ns/div in a 1-2-5 sequence or calibrated variable control, 1.25 s/div to 50 ns/div.
    (PM 3390B/3394B): 0.5 s/div to 20 ns/div in a 1-2-5 sequence or calibrated variable control, 1.25 s/div to 20 ns/div. 
    Fastest Sweep (Magn 10X): (PM 3380B/3384B) 5 ns/div
    (PM 3390B/3394B) 2 ns/div
    Error Limit (Magn 10X):  ±1.3% of reading + 0.5% of 8 divisions)
     
    Triggering (Main & Delayed Timebase) Trigger modes: Auto free run, Triggered, Single, Edge Triggering, TV Triggering 
     
    Edge Triggering MTB Trigger Source: (PM 3380B/3390B): Ch1, Ch2, Ext
    (PM 3384B/3394B): Any input channel or Line (mains); Optional rear mounted External Trigger input replacing line Triggering.
    DTB Trigger Source: Starts after delay or triggered on any input channel. 
    Slope: Positive or Negative 
    Coupling: DC, AC (> 10 Hz), LF-Rej (30 kHz), HF-Rej (30 kHz) 
    Level Range: ±8 div or level within signal peak to peak range. 
    Level Indication:  On screen level indicators and numeric readout.
    Trigger Sensitivity: (PM 3380B/3384B): 0.6 div up to 50 MHz, 1.2 div up to 100 MHz, 2.0 div up to 200 MHz
    (PM 3390B/3394B): 0.6 div up to 100 MHz, 1.2 div up to 200 MHz, 2.0 div up to 300 MHz 
     
    TV Triggering Video Standard: HDTV, NTSC, PAL, SECAM standards
    MTB Trigger Source: CH1 to CH4, Field1, Field2, TV-Lines 
    Signal Polarity: Positive or Negative 
    Sensitivity: 0.7 div (Sync Pulse) 
     
    Cursor Measurements Cursor Modes: Horizontal, Vertical, Both 
    Readout: Vertical: dV, V1 to gnd, V2 to gnd, Ratio 
    Horizontal: dt, 1/dt (in Hz), Ratio, Phase
    Accuracy (magn 1X): 1% of full scale within the central 8 horizontal and 6 vertical divisions.
     
    X-Y Mode X Deflection Source: Any input channel or line
    X Deflection Coefficient: Same as for vertical deflection 
    Dynamic range: 20 div up to 100 kHz, > 10 div up to 2 MHz. 
    Frequency Response: 32 MHz at -3 dB 
    Error Limit: 5% measured over central 6 divisions. 
    Phase Shift: < 3o up to 100 kHz 
     


     
    PM3380BDigital Mode Specifications
    Acquisition Repetitive Sample Rate: Random sampling gives an equivalent sample rate of up to; 
    (PM 3380B/3384B): 10 GS/s
    (PM 3390B/3394B): 25 GS/s
    Single Shot Sample Rate: Up to 200 MS/s
    Vertical resolution: ADC resolution: 8 bit
    Memory resolution: 16 bit
    Memory: (PM 3380B/3390B): Standard Memory: 8 k, max trace storage, 27 traces
    (PM 3380B/3390B): Extended Memory option: 32 k, max trace storage, 153 traces
    (PM 3384B/94B): Standard Memory: 32 k, max trace storage, 204 traces 
    Average:  2,4,8 to 4096, giving a resolution of up to 14 bits
    Peak Detection: Captures glitches up to 5 ns
    Envelope Mode:  For continuous tracking of changing waveforms 
     
    Vertical Auto Ranging vertical deflection: Automatically and continuously adapts the instrument's vertical settings to have 2 to 6 divisions' display of input signal.
    Bandwidth: See above analog mode specification 
    Magnification: Up to x32 magnification for higher deflection sensitivity. 
    Display modes: Ch1, ± Ch2, Ch3, ± Ch4, calculated add and subtract
    Window Mode: 2 or 4 windows to display two or four traces above each other while using the full dynamic range of the ADC 
     
    Horizontal Autoranging timebase: Continuously adapts timebase sweep speed to the frequency of the trigger signal in order to keep 2 to 6 cycles on screen. 
    Acquisition modes: Recurrent (Auto and triggered), Single Shot, Multiple Single Shot, Roll, Triggered Roll
    X-Y Mode: Any trace in memory or any of the input channels can be used as a X source. 
     
    Timebase Single Shot Sampling:  200 s/div to 500 ns/div in a 1-2-5 sequence
    Variable Timebase: Continuously variable sweep speed; 1us/div to 500 us/div in 1 us increments. 500 us/div to 200 s/div with 0.2% or smaller increments.
    Recurrent:  (PM 3380B/3384B): 200 ns/div to 5 ns/div 
    (PM 3390B/3394B): 200 ns/div to 2 ns/div
    Roll Mode: 200 s/div to 200 ms/div, triggered or free roll mode, in a 1-2-5 sequence or continuously variable 
    Display Resolution: Horizontal resolution for 1x magnification: 500 samples = 10 divisions = 1 screen width.
    Magnification: x2, x4 to x32 to zoom in onto parts of waveform
    Interpolation: Dots, Sine or Linear
     
    Triggering Trigger Coupling: Same as analog mode 
    Edge Triggering:  Same as analog mode plus; dual slope triggering available when in single shot, real time mode. 
    TV Triggering: Same as analog mode 
    Logic trigger modes: (PM 3380B/3390B): Glitch (time qualified pulse)
    (PM 3384B/3394B): State (4 bit), Pattern (4 bit), Glitch (time qualified pulse) 
     
    Delay Time Delay: 0 to 1,000 div continuously adjustable
    Pre trigger view: Up to a complete record can be filled with pre-trigger information. (160 div for 8 k, 640 division for 32 k) 
    Event Delay: 1 to 16,384 events, max count rate 50 MHz
    Delay Modes: Starts after time delay or wait for trigger after time delay.
     
    Cursor Measurements Cursor Modes: Horizontal, Vertical, Both: Free or locked to trace
    Readout: Vertical: dv, V1 to gnd, V2 to gnd, Ratio
    Horizontal: dt, 1/dt (in Hz), Ratio, Phase (cycle is automatically referenced to trigger signal) 
     
    Calculated Measurements Volt: DC, rms, minimum, maximum, peak to peak, Low level, High level, Overshoot (positive & negative), Pre-shoot (positive & negative)
    Time: Frequency, Period, Pulsewidth, Rise time, Fall time, Duty cycle 
    Delay: Channel to channel, rising and falling edges. 
    Quick Measurements Probe operated, "Touch Hold And Measure" instantly gives calculated measurements of frequency, dc, rms, and Vp-p.
     
    Processing Add, Subtract, Multiply, Digital Filter, Integrate, Differentiate, FFT, Histogram, Pass Fail.
     


    PM3380BGeneral Specifications
    Autoset Selects proper channel, time-base and trigger settings. Function can be customized
     
    Autocal Automatic fine adjustment for enhanced accuracy to get optimal performance even under extreme environmental conditions
     
    Interfacing Standard: RS-232C, CPL protocol 
    Options: IEEE-488.2(GPIB), SCPI
     
    Hard Copy Output: Printed or plotted hard copy of the screen in digital mode. 
    User Text: Two lines of on-screen text
    Interface: RS-232C or IEEE-488.2 (GPIB) 
    Printer Drivers: FX Series (9 Pin), LQ1500 (24 Pins), HP 2225 Thinkjet, HP Laserjet, (series II & III), HP 540 Deskjet, and compatibles.
    Plotters: HP 7440, HP 7550, HP 7475A, HP 7470A and compatibles, HPGL. 
    Camera: Camera Kit PM 9381/001 available as optional accessory. 
     
    Power Supply Line Voltage: 100V to 240V (±10%) CAT II 
    Line Frequency: 50 Hz to 400 Hz (±10%) 
    Power Consumption: 115W (130W with all options installed) 
     
    Safety Meets requirements of EN 61010-1 CAT II Pollution Degree 2, Low Voltage Directive 73/23/EEC, UL3111, CSA C22.2 010-1
    Meets requirements of MIL-STD-461C: Part2 CEO1 (narrow band), Part4 CEO3, Part2 CSO1, Part5 CSO6, (Limited to 300V), Part5 and 6 REO1, Part2 REO2 (max. 1 GHz)
     
    EMC 
    Miscellaneous Setting Memory: 10 complete instrument setups, with battery backup. 
    Calibrated output: 600 mv p-p, 2 kHz square wave. 
    Z-Modulation Input: BNC, 10 kΩ > 2.4V=blanked, < 0.5 V=unblanked 
    Time Between Calibration: 2000 Hrs or 1 year
    4000 Hrs or 2 year if error limits are doubled.
     
    Size (excluding handle & feet) 139 mm H x 341 mm W x 481 mm L
    5.5" H x 13.4" W x 18.9' L
     
    Weight  9.5 kg
    21 lb
     
    Warranty Three-year product warranty, parts and labor. Five year CRT warranty.
     

     

    在線咨詢

    留言框

    • 產(chǎn)品:

    • 您的單位:

    • 您的姓名:

    • 聯(lián)系電話:

    • 常用郵箱:

    • 省份:

    • 詳細(xì)地址:

    • 補(bǔ)充說(shuō)明:

    • 驗(yàn)證碼:

      請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7

    掃碼添加微信

    • 蘇州高新區(qū)長(zhǎng)江路436號(hào)綠寶商務(wù)樓2幢7003室
    • 聯(lián)系電話:0512-68051240
    • 公司郵箱:chunjing_liu@yoi-tech.com

    © 2025 詠繹電子科技(蘇州)有限公司(m.7474ll.com) 版權(quán)所有    

    技術(shù)支持:化工儀器網(wǎng)    管理登陸    sitemap.xml

    TEL:

    掃碼聯(lián)系我們

    主站蜘蛛池模板: 亚洲∧v久久久无码精品| 国产福利91精品一区二区| 92国产精品午夜福利| 久久久人妻精品无码一区| 国产亚洲精品国产| 亚洲αv在线精品糸列| 久久91这里精品国产2020| 99免费精品国产| 久久久久亚洲精品天堂久久久久久| 日本免费精品一区二区三区| 久久精品国产一区二区三区日韩| 精品国产一区二区三区免费| 伊人精品久久久久7777| jizz国产精品| 国内精品在线视频| 精品亚洲国产成AV人片传媒| 香港aa三级久久三级老师2021国产三级精品三级在 | 91亚洲精品麻豆| 国产成人亚洲精品青草天美| 中文字幕日韩精品有码视频| 久久国产成人亚洲精品影院| 国产叼嘿久久精品久久| 欧美精品/日韩精品/国产精品| 国产偷伦精品视频| 日韩精品在线一区二区| 大伊香蕉精品视频在线导航| 久久久精品人妻一区二区三区蜜桃 | 欧美精品中文字幕亚洲专区| 亚洲国产精品自在拍在线播放| 国产精品免费无遮挡无码永久视频| 欧美精品免费在线| 国产精品网站在线观看| 国产精品亚洲片在线| 无码人妻精品一区二区三区夜夜嗨| 成人精品一区二区三区在线观看| 中文字幕日本精品一区二区三区| 国内精品伊人久久久久| 国产精品一区二区久久精品| 国产欧美精品AAAAAA片| 国内精品久久久久久99| 99久久久精品免费观看国产|